CSC 523973.10 – Cab Suspension Fails to Reach Level Position or End Stops in Target Time During Calibration. John Deere System Advisory.

CSC 523973.10 (CSC )

Code: 523973.10

Shortcode:

Description:

Error code CSC 523973.10 indicates that during the calibration of the cab suspension, the system fails to reach the level position or end stops within the specified time limit. This condition may suggest a fault in the raise/lower solenoid valves.

Reaction:

The calibration process fails, and the system requires a restart of the bleeding and calibration process.

Recommendations:

  • Inspect Solenoid Valves: Check the raise/lower solenoid valves for any faults or malfunctions. Ensure they are operating correctly and replace any faulty valves.
  • Verify Electrical Connections: Examine all electrical connections to the solenoid valves for damage or loose connections and repair as necessary.
  • Measure System Performance: Use diagnostic tools to measure the performance of the solenoid valves and ensure the cab suspension system operates within specified parameters.
  • Review and Calibrate Control Software: Ensure the control software is up-to-date and properly configured for the calibration process.
  • Perform System Bleeding and Calibration: After addressing any issues, restart the bleeding process and perform a full calibration to ensure the cab suspension reaches the level position and end stops within the target time.

Note:

Accurate and timely calibration of the cab suspension system is essential for maintaining optimal performance and safety. Regular maintenance and prompt resolution of issues related to solenoid valves and electrical connections help ensure reliable operation.


Control Units: John Deere

John Deere Parts
John Deere Logo