EPC 000177.04 – B60 Sensor for Transmission Oil Temperature, Voltage Too Low
EPC 000177.04 (EPC 177.04)
Code: 000177.04
Shortcode: 177.04
Description:
This error code, EPC 000177.04, indicates that the control unit has detected a voltage that is too low at the signal input of the transmission oil temperature sensor (lead 6002). This typically means the temperature value is above 125°C (257°F), suggesting a short to ground in the sensor circuit.
Reaction:
When this error is detected, the control unit may not accurately monitor the transmission oil temperature, which can lead to improper transmission operation and potential damage due to overheating.
Recommendations:
Inspect Sensor Wiring:
- Check the wiring associated with the transmission oil temperature sensor (B60) for any signs of shorts to ground. Repair or replace any damaged wiring.
Test Sensor Functionality:
- Use diagnostic tools to test the transmission oil temperature sensor. Replace the sensor if it is found to be faulty.
Verify Connections:
- Ensure all connectors and terminals in the sensor circuit are secure and free of corrosion. Repair or replace any faulty connections.
Check for Ground Faults:
- Use a multimeter to check for ground faults in the sensor circuit. Resolve any detected faults.
Reset and Test System:
- After addressing the issues, reset the system and monitor the transmission oil temperature readings to ensure they are accurate.
Note:
Ensuring the integrity of sensor wiring and connections is crucial for accurate temperature monitoring and proper transmission operation. Regular checks can help prevent such issues and ensure reliable performance.