ETC 000168.03 – Control Unit, Supply Voltage Too High

ETC 000168.03 (ETC 168.03)

Code: 000168.03

Shortcode: 168.03

Description:

The error code ETC 000168.03 is triggered when the control unit detects a supply voltage exceeding 16 volts. This condition is specifically monitored at pin 22, lead 0402 (ELX). Excessive supply voltage can be caused by issues such as a malfunctioning voltage regulator, alternator overcharging, or wiring problems that lead to high voltage spikes. This can potentially damage sensitive electronic components within the control unit.

Reaction:

When this fault is detected, the control unit may limit its functionality to prevent damage. This can result in reduced performance or a complete shutdown of certain systems to protect the electrical components from overvoltage damage.

Recommendations:

Inspect the Charging System:

  • Check the Alternator Output: Use a multimeter to measure the voltage output from the alternator. Ensure it is within the manufacturer’s specified range (usually between 13.5 and 14.5 volts).
  • Test the Voltage Regulator: Verify the operation of the voltage regulator to ensure it is maintaining the correct output voltage. Replace the regulator if it is found to be faulty.

Examine Electrical Connections:

  • Inspect Wiring for Damage: Look for any signs of damaged, frayed, or corroded wiring that could cause voltage spikes. Repair or replace any compromised wiring.
  • Check Ground Connections: Ensure all ground connections are secure and free of corrosion, as poor grounding can lead to incorrect voltage readings.

Evaluate Battery Health:

  • Test the Battery: Use a battery tester to check the condition and charge level of the battery. Replace the battery if it is not holding a charge or is found to be defective.
  • Inspect Battery Terminals: Clean and tighten battery terminals to ensure a good connection.

Update Control Unit Software:

  • Firmware Updates: Check for any available firmware updates for the control unit that may address voltage monitoring issues or improve tolerance to voltage fluctuations.

Note:

Consistently monitoring the vehicle’s electrical system and ensuring all components are functioning correctly is crucial in preventing overvoltage issues. Regular maintenance checks can help identify potential problems before they lead to equipment failure. Additionally, using high-quality electrical components and adhering to manufacturer specifications will contribute to the reliable operation of the control unit and associated systems.