ETC 000876.01 – M02 Compressor Clutch, Power Supply Fault at Power Module (HF) PC6

ETC 000876.01 (ETC 876.01)

Code: 000876.01

Shortcode: 876.01

Description:

The error code ETC 000876.01 is generated when the power module (HF) PC6 measures less than 3 volts at the supply voltage for the compressor clutch output (lead 0732) when the compressor clutch (M02) is switched on. This indicates a power supply fault in the circuit.

Reaction:

When this fault is detected, the power module may deactivate the compressor clutch to prevent damage due to insufficient power supply. This can result in the air conditioning system not functioning properly.

Recommendations:

Inspect Power Supply:

  • Check Supply Voltage: Use a multimeter to measure the supply voltage at the compressor clutch output. Ensure it is above 3 volts when the clutch is activated.
  • Inspect Wiring and Connections: Examine the wiring and connectors for the compressor clutch for signs of damage, loose connections, or corrosion. Repair or replace any compromised wiring.

Test and Replace Components:

  • Test Compressor Clutch: Verify the operation of the M02 compressor clutch. Replace the clutch if it is found to be defective or causing a power supply fault.
  • Inspect Power Module: Ensure that the power module (HF) PC6 is functioning correctly. Replace the power module if it is found to be faulty.

Repair or Replace Wiring:

  • Fix Damaged Wiring: Repair or replace any damaged or faulty wiring in the compressor clutch circuit. Ensure all connections are secure and properly insulated.

Note:

Maintaining a stable power supply to the compressor clutch is essential for the reliable operation of the air conditioning system. Regular inspection and maintenance of the electrical connections can help prevent power supply faults and ensure proper system performance.


Control Units: John Deere