ETC 000876.05 – M02 Compressor Clutch On, No Current Present at Power Module (HF) PC6

ETC 000876.05 (ETC 876.05)

Code: 000876.05

Shortcode: 876.05

Description:

The error code ETC 000876.05 is triggered when the power module (HF) PC6 measures less than 350 mA at the compressor clutch output (lead 2023) while the compressor clutch (M02) is switched on. This indicates that the circuit is open, meaning there is no current flowing through the circuit as expected.

Reaction:

When this fault is detected, the control unit may disable the compressor clutch to prevent further damage and ensure safe operation. This will result in the air conditioning system not functioning properly.

Recommendations:

Inspect Electrical Circuits:

  • Check for Open Circuits: Examine the wiring and connectors for the compressor clutch for signs of open circuits or disconnections. Look for broken wires, loose connections, or corroded terminals.
  • Measure Current Flow: Use a multimeter to measure the current flow in the compressor clutch circuit to ensure it is within the expected range (above 350 mA).

Test and Replace Components:

  • Test Compressor Clutch: Verify the operation of the M02 compressor clutch. Replace the clutch if it is found to be defective or not drawing the expected current.
  • Inspect Power Module: Ensure that the power module (HF) PC6 is functioning correctly. Replace the power module if it is found to be faulty.

Repair or Replace Wiring:

  • Fix Broken Wires: Repair or replace any identified open circuits or disconnected wiring. Ensure all connections are secure and properly insulated.

Note:

Regular maintenance and inspection of the electrical connections in the air conditioning system can help prevent open circuit issues. Ensuring proper routing and securing of wires can reduce the risk of disconnections and enhance system reliability.