ETC 001552.04 – Temperature Control, Voltage Too Low

ETC 001552.04 (ETC 1552.04)

Code: 001552.04

Shortcode: 1552.04

Description:

The error code ETC 001552.04 is triggered when the control unit measures 0 volts at the signal input of the temperature control. This indicates a short to ground in the internal circuit of the control unit.

Reaction:

When this fault is detected, the control unit may disable or limit the operation of the temperature control to prevent malfunction due to lack of signal. This can result in incorrect temperature regulation.

Recommendations:

Inspect Electrical Circuits:

  • Check for Shorts to Ground: Inspect the wiring and connectors for the temperature control for signs of short circuits to ground. Look for damaged insulation, exposed wires, or pinched cables.
  • Measure Voltage: Use a multimeter to measure the voltage at the signal input of the temperature control to ensure it is within the specified range.

Test and Replace Components:

  • Test Temperature Control: Verify the operation of the temperature control component. Replace if it is found to be malfunctioning or not providing the correct signal.
  • Inspect Control Unit: Ensure that the control unit is functioning correctly. Replace the control unit if it is found to be faulty.

Repair or Replace Wiring:

  • Fix Damaged Wiring: Repair or replace any damaged or shorted wiring in the temperature control circuit. Ensure all connections are secure and properly insulated.

Note:

Maintaining the integrity of the electrical connections is crucial for the reliable operation of the temperature control system. Regular inspection and timely repairs of the electrical system can help prevent issues related to low voltage and ensure proper system performance.


Control Units: John Deere