ICC 002807.06 – Engine Fuel Shutoff 2 Control Current Above Normal or Grounded Circuit

ICC 002807.06 (ICC 2807.06)

Code: 002807.06

Shortcode: 2807.06

Description:

This code indicates that the current for the engine fuel shutoff 2 control is above normal or the pull-in coil output circuit is shorted to ground. This could be due to a short circuit in the wiring, a defective pull-in coil, or problems with the control module.

Reaction:

The engine may not shut off correctly, leading to potential safety hazards and operational issues. The operator might see a warning light on the dashboard.

Recommendations:

  • Inspect Fuel Shutoff Pull-In Coil:
    • Check the pull-in coil for proper operation and signs of short circuits.
    • Replace the pull-in coil if necessary.
  • Examine Wiring for Shorts:
    • Inspect the wiring harness for signs of damage or shorts to ground.
    • Repair or replace any damaged wiring.
  • Test Control Module:
    • Verify the functionality of the control module responsible for the fuel shutoff system.
    • Replace the control module if necessary.
  • Check for Grounding Issues:
    • Ensure the fuel shutoff circuit is not improperly grounded.

Note:

Routine checks and maintenance of the electrical system and fuel shutoff components can help prevent issues with the pull-in coil and ensure reliable operation.