ICC 002807.06 – Engine Fuel Shutoff 2 Control Current Above Normal or Grounded Circuit
ICC 002807.06 (ICC 2807.06)
Code: 002807.06
Shortcode: 2807.06
Description:
This code indicates that the current for the engine fuel shutoff 2 control is above normal or the pull-in coil output circuit is shorted to ground. This could be due to a short circuit in the wiring, a defective pull-in coil, or problems with the control module.
Reaction:
The engine may not shut off correctly, leading to potential safety hazards and operational issues. The operator might see a warning light on the dashboard.
Recommendations:
- Inspect Fuel Shutoff Pull-In Coil:
- Check the pull-in coil for proper operation and signs of short circuits.
- Replace the pull-in coil if necessary.
- Examine Wiring for Shorts:
- Inspect the wiring harness for signs of damage or shorts to ground.
- Repair or replace any damaged wiring.
- Test Control Module:
- Verify the functionality of the control module responsible for the fuel shutoff system.
- Replace the control module if necessary.
- Check for Grounding Issues:
- Ensure the fuel shutoff circuit is not improperly grounded.
Note:
Routine checks and maintenance of the electrical system and fuel shutoff components can help prevent issues with the pull-in coil and ensure reliable operation.