ICC 003695.03 – Diesel Particulate Filter Regeneration Inhibit Switch Voltage Above Normal, or Shorted to High Source

ICC 003695.03 (ICC 3695.03)

Code: 003695.03

Shortcode: 3695.03

Description:

This code indicates that the voltage for the Diesel Particulate Filter (DPF) regeneration inhibit switch is above normal, suggesting that the switch is stuck on or there is a short to power. This could be due to a faulty switch, wiring issues, or problems within the control module.

Reaction:

The DPF regeneration process may be inhibited, leading to an accumulation of soot in the filter, increased emissions, and potential engine performance issues. The operator might see a warning light or message on the dashboard.

Recommendations:

  • Inspect Inhibit Switch:
    • Check the DPF regeneration inhibit switch for proper operation. Replace the switch if it is found to be defective.
  • Examine Wiring and Connectors:
    • Inspect the wiring harness and connectors associated with the inhibit switch for signs of damage, corrosion, or loose connections.
    • Repair or replace any damaged components.
  • Test Control Module:
    • Verify the functionality of the control module managing the inhibit switch.
    • Update the control module software to the latest version.
  • Check for Voltage Issues:
    • Use a multimeter to check for proper voltage levels in the inhibit switch circuit.
    • Repair any issues with high voltage or short circuits.

Note:

Regular inspection and maintenance of the DPF system and associated switches can help prevent issues and ensure proper operation of the regeneration process.


Control Units: John Deere

John Deere Parts
John Deere Logo