PL3 003597.06 – Output for Driver, Current Too High
PL3 003597.06 (PL3 3597.06)
Code: 003597.06
Shortcode: 3597.06
Description:
This diagnostic trouble code is generated when the control unit for range shifting (DirectDrive transmission) detects a current that is too high at the driver output. The driver outputs at the control unit are switched off to prevent damage.
Reaction:
The control unit switches off driver outputs to protect the system from potential damage due to excessive current.
Recommendations:
Inspect Electrical Components:
- Check all electrical components related to the control unit for signs of damage or short circuits. Repair or replace any faulty components.
Examine Wiring and Connections:
- Inspect wiring and connections for damage, wear, or corrosion. Repair or replace as necessary to ensure proper current flow.
Test Control Unit:
- Test the control unit to ensure it is functioning correctly. Replace the control unit if it is found to be defective.
Check for Obstructions:
- Ensure there are no obstructions or mechanical issues that could cause excessive current draw.
Note:
Excessive current can cause severe damage to electrical systems. Address this issue promptly to avoid further complications.