PLC 328102.31 – B90 Park Lock Pressure Sensor, Supply Voltage Too High
PLC 328102.31 (PLC )
Code: 328102.31
Shortcode:
Description:
This diagnostic trouble code is generated when the PLC control unit detects a voltage of more than 5.4 volts at the positive power supply lead for the park lock pressure sensor (B90). This indicates a short to a supply lead somewhere in the circuit.
Reaction:
The park lock pressure sensor may provide inaccurate readings, potentially affecting the park lock system’s ability to function correctly.
Recommendations:
- Inspect Wiring and Connections:
- Check for any signs of damage, corrosion, or loose connections in the wiring to the B90 park lock pressure sensor. Repair or replace as necessary.
- Check for Shorts to Supply Lead:
- Inspect the circuit for any shorts to a supply lead and address any issues found.
- Test the Sensor:
- Verify the functionality of the B90 park lock pressure sensor. Replace if faulty.
- Secure Connections:
- Ensure all connections are secure and free from contamination.
Note:
Maintaining clean and secure connections is crucial to prevent high voltage issues in sensor circuits. Regular inspections can help identify and address potential problems before they lead to faults.