PTD 002006.09 – Incorrect CAN Bus Message, Information from EIC Control Software

PTD 002006.09 (PTD 2006.09)

Code: 002006.09

Shortcode: 2006.09

Description:

This diagnostic trouble code is generated when a data transfer problem occurs between the PTD control software and the EIC control software. Messages sent on the CAN Bus by the EIC control software are either intermittent or non-existent, indicating a potential issue such as an open circuit, short circuit, or faulty CAN Bus terminators.

Reaction:

When this error is detected, the control software may have limited or no functionality, affecting the overall operation of the equipment.

Recommendations:

Inspect CAN Bus Wiring:

  • Check all CAN Bus wiring for any signs of damage, wear, or loose connections.
  • Repair or replace any damaged wires or connectors.

Test CAN Bus Terminators:

  • Verify that the CAN Bus terminators are functioning correctly.
  • Replace any faulty terminators.

Check for Short Circuits:

  • Inspect the CAN Bus for any potential short circuits.
  • Repair any identified short circuits.

Verify EIC and PTD Connections:

  • Ensure that the connections between the EIC and PTD control software are secure and free from corrosion.

Consult Technical Support:

  • If the issue persists, consult technical support or a qualified technician for further diagnosis and repair.

Monitor System:

  • After performing repairs, monitor the CAN Bus communication to ensure it is functioning correctly.

Note:

Regular inspection and maintenance of the CAN Bus system can help prevent communication issues and ensure reliable operation of the control software.


Control Units: John Deere

John Deere Parts
John Deere Logo