PTF 000186.01 – Front PTO Speed Sensor, Overload Protection Activated

PTF 000186.01 (PTF 186.01)

Code: 000186.01

Shortcode: 186.01

Description:

This error code is generated when the control software detects that the front PTO does not start up correctly after being turned on. The front PTO is turned off and can only be restarted after 30 seconds. This indicates that the front PTO is overloaded due to a blocked or sluggish implement or excessive slip at the front PTO clutch.

Reaction:

When this code is detected, the front PTO is turned off and can only be turned back on again after 30 seconds.

Recommendations:

  • Inspect PTO Implement:
    • Check the implement connected to the front PTO for blockages or sluggish operation.
    • Clear any blockages and ensure the implement operates smoothly.
  • Check PTO Clutch:
    • Inspect the front PTO clutch for excessive slip.
    • Adjust or replace the clutch as needed.
  • Monitor PTO Load:
    • Ensure that the load on the front PTO is within the specified limits.
    • Avoid overloading the PTO with heavy or improperly functioning implements.

Note:

Proper maintenance of the front PTO and connected implements can prevent overload conditions and ensure smooth operation.