PTR 000190.18 – Engine Speed Missing During Shift
PTR 000190.18 (PTR 190.18)
Code: 000190.18
Shortcode: 190.18
Description:
This error code, PTR 000190.18, is generated by the Power Train Reverser (PTR) control unit when it detects that the engine speed signal drops below 400 rpm for more than 2 seconds during a shift. This can occur due to a malfunctioning engine speed sensor, wiring issues, or problems within the engine control system.
Reaction:
When this error is detected, the PTR control unit may interrupt the shifting process to prevent potential damage to the transmission. The system may also display a warning message to the operator.
Recommendations:
Inspect Engine Speed Sensor:
- Check the engine speed sensor for proper operation.
- Ensure the sensor is not damaged, dirty, or misaligned. Replace if necessary.
Check Wiring and Connections:
- Inspect the wiring and connectors related to the engine speed sensor.
- Ensure all connections are secure and free from corrosion or damage.
Test Sensor Circuitry:
- Use a multimeter to test the engine speed sensor circuitry for proper functionality.
- Ensure there are no short circuits or open circuits causing the signal loss.
Examine Engine Control System:
- Verify that the engine control system is functioning correctly.
- Check for any diagnostic trouble codes in the engine control unit that might relate to engine speed issues.
Update Software:
- Ensure that the PTR control unit and engine control unit software are up-to-date.
- Apply any available software updates or patches from the manufacturer.
Monitor Engine Speed Signal:
- After addressing the issue, monitor the engine speed signal during operation.
- Ensure that the signal remains stable and does not drop below 400 rpm during shifts.
Note:
Accurate engine speed signals are critical for proper shifting and transmission performance. Regular maintenance of the engine speed sensor and related components can help prevent such issues.