PTR 000752.04 – Power Shuttle Potentiometer Input Voltage Low

PTR 000752.04 (PTR 752.04)

Code: 000752.04

Shortcode: 752.04

Description:

This error code, PTR 000752.04, is generated by the Power Train Reverser (PTR) control unit when it detects that the shuttle sensor voltage is below the minimum voltage limit (0.2 V) for more than 5 seconds. This can occur due to a faulty potentiometer, wiring issues, or problems within the control circuitry.

Reaction:

When this error is detected, the PTR control unit may disable the shuttle functionality to prevent potential damage. The system may also display a warning message to the operator.

Recommendations:

Inspect Shuttle Potentiometer:

  • Check the shuttle potentiometer for proper operation.
  • Ensure the potentiometer is not stuck, damaged, or worn out. Replace if necessary.

Check Wiring and Connections:

  • Inspect the wiring and connectors related to the shuttle potentiometer.
  • Ensure all connections are secure and free from corrosion or damage.

Test Potentiometer Circuitry:

  • Use a multimeter to test the potentiometer circuitry for proper functionality.
  • Ensure there are no short circuits or open circuits causing the low voltage signal.

Examine Control Unit:

  • Verify that the PTR control unit is functioning correctly.
  • Check for any diagnostic trouble codes in the control unit that might relate to the shuttle system.

Update Software:

  • Ensure that the PTR control unit software is up-to-date.
  • Apply any available software updates or patches from the manufacturer.

Monitor Shuttle Operation:

  • After addressing the issue, monitor the shuttle operation during use.
  • Ensure that the shuttle potentiometer provides a consistent and accurate voltage signal.

Note:

Proper shuttle operation is critical for safe and efficient transmission performance. Regular inspection and maintenance of the shuttle potentiometer and related components can help prevent such issues.


Control Units: John Deere

John Deere Parts
John Deere Logo