RLC 521560.03 – Right Outer Worklight on Rear of Roof or Right Turn-Signal Light on Rear of Roof (SAE), Voltage Too High

RLC 521560.03 (RLC )

Code: 521560.03

Shortcode:

Description:

This diagnostic trouble code is generated if a voltage higher than the expected value is registered at the output to the right outer worklight on the rear of the roof or right turn-signal light on the rear of the roof (SAE). This indicates that the circuit is open or shorted to 12 volts.

Reaction:

When this error is detected, the control software may experience limited or no functionality of the worklight or the turn-signal light.

Recommendations:

  • Inspect Light Circuit:
    • Check the wiring and connectors associated with the right outer worklight or right turn-signal light for signs of open circuits or shorts to 12 volts. Look for damaged insulation or exposed wires. Repair or replace any compromised wiring.
  • Verify Voltage Regulation:
    • Ensure the voltage regulator is functioning correctly and maintaining proper voltage levels. Replace the regulator if it is faulty.
  • Test Lights:
    • Test the right outer worklight or right turn-signal light to ensure they are not damaged or causing the voltage increase. Replace any faulty light components.
  • Check Power Supply:
    • Ensure the power supply to the lights is stable and within the specified range. Inspect for any issues that could cause an overvoltage condition.

Note:

Excessive voltage can damage the lights and associated circuitry. Regular inspection and maintenance of the electrical system are essential to prevent such issues.


Control Units: John Deere

John Deere Parts
John Deere Logo