RLC 521567.06 – Turn-Signal Lights, Current Too High
RLC 521567.06 (RLC )
Code: 521567.06
Shortcode:
Description:
This diagnostic trouble code is generated if the control software registers that the current at the output to the turn-signal lights is too high. This indicates a short circuit to ground.
Reaction:
When this error is detected, the control software may experience limited or no functionality of the turn-signal lights.
Recommendations:
- Inspect Turn-Signal Circuit:
- Check the wiring and connectors associated with the turn-signal lights for signs of short circuits to ground. Look for damaged insulation or exposed wires. Repair or replace any compromised wiring.
- Test Turn-Signal Lights:
- Test the turn-signal lights to ensure they are not damaged or causing excessive current draw. Replace any faulty light components.
- Verify Power Supply:
- Ensure the power supply to the turn-signal lights is stable and within the specified range. Inspect for any issues that could cause an overcurrent condition.
Note:
Excessive current can damage the turn-signal lights and associated circuitry. Regular inspection and maintenance of the electrical system are essential to prevent such issues.