RLC 522343.03 – Heated Rear Window, Voltage Too High

RLC 522343.03 (RLC )

Code: 522343.03

Shortcode:

Description:

This diagnostic trouble code is generated if a voltage higher than 16 volts is registered at the output to the heated rear window. This indicates that the circuit is shorted to a supply lead.

Reaction:

When this error is detected, the control software may experience limited or no functionality of the heated rear window.

Recommendations:

  • Inspect Heated Rear Window Circuit:
    • Check the wiring and connectors associated with the heated rear window for signs of shorts to a supply lead. Look for damaged insulation or exposed wires. Repair or replace any compromised wiring.
  • Verify Voltage Regulation:
    • Ensure the voltage regulator is functioning correctly and maintaining proper voltage levels. Replace the regulator if it is faulty.
  • Test Heated Rear Window:
    • Test the heated rear window to ensure it is not damaged or causing the voltage increase. Replace any faulty components.
  • Check Power Supply:
    • Ensure the power supply to the heated rear window is stable and within the specified range. Inspect for any issues that could cause an overvoltage condition.

Note:

Excessive voltage can damage the heated rear window and associated circuitry. Regular inspection and maintenance of the electrical system are essential to prevent such issues.


Control Units: John Deere

John Deere Parts
John Deere Logo