RPT 523813.12 – Solenoid for PTO Speed 1 Off, Current Present at PAP Control Software
RPT 523813.12 (RPT )
Code: 523813.12
Shortcode:
Description:
This diagnostic trouble code, RPT 523813.12, is generated when the PAP control software measures a current of more than 1 A at the output to the solenoid for PTO speed 1 when the solenoid is turned off. This indicates a short in the circuit or an internal fault of the control software.
Reaction:
When this error is detected, the functionality of the rear PTO is significantly limited or entirely non-functional.
Recommendations:
Inspect Solenoid Circuit:
- Check the wiring and connections for the solenoid circuit for signs of a short.
- Repair or replace any damaged wires or connectors.
Test Solenoid and Control Software:
- Use diagnostic tools to measure the current levels and test the solenoid for proper operation.
- Replace the solenoid if it is found to be faulty.
Check for Internal Faults:
- Inspect the PAP control software for any internal faults that could be causing the issue.
- Update the control software to the latest version and apply any available patches.
Consult Technical Support:
- If the problem persists, consult with technical support or the equipment manufacturer for further assistance.
- Provide detailed error logs and current measurements to aid in troubleshooting.