SCC 524105.31 – SCV II Control Lever Command Missing

SCC 524105.31 (SCC )

Code: 524105.31

Shortcode:

Description:

This error code indicates that the SCV II (Selective Control Valve II) lever position data has not been received via CAN message. This can be due to communication issues, improper configuration, or a faulty lever.

Reaction:

When this code is detected, the SCC will disable the functions related to SCV II to prevent further issues.

Recommendations:

Verify Configuration:

  • Check the configuration of the SCV II control lever. Ensure it is correctly configured according to the manufacturer’s guidelines.

Inspect SCV II Control Lever:

  • Verify the functionality of the SCV II control lever. Replace the lever or sensor if it is found to be faulty.

Check Wiring and Connectors:

  • Inspect all wiring and connectors associated with the SCV II control lever for signs of damage, poor connections, or corrosion. Repair or replace as necessary.

Monitor CAN Messages:

  • Use diagnostic tools to monitor CAN messages from the SCV II control lever to the SCC, ensuring they are being received.

Update Firmware and Software:

  • Ensure all relevant components, including the SCC, have the latest firmware and software updates.

Consult Technical Support:

  • If the issue persists, contact technical support for further diagnostics and assistance.

Note:

Proper configuration and reliable communication are crucial for the accurate operation of SCV II.


Control Units: John Deere

John Deere Parts
John Deere Logo